Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Rehabil Res Clin Transl ; 4(3): 100202, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36123975

RESUMO

Objective: To develop and test an assessment measuring extended physiological proprioception (EPP). EPP is a learned skill that allows one to extend proprioception to an external tool, which is important for controlling prosthetic devices. The current study examines the ability of this assessment to measure EPP in a nonamputee population for translation into the affected population. Design: Measuring precision and accuracy of an upper extremity (UE) proprioceptive targeting task assessment. Participants completed 2 sessions of a targeting task while seated at a table. The targeting was completed with the dominant and nondominant hand and with eyes open and eyes closed during the task. Participants completed 2 sessions of the clinical test with a 1-week washout period to simulate reasonable time between clinical visits. Setting: Research laboratory. Participants: Twenty right-handed participants (N=20) with no neurologic or orthopedic deficits that would interfere with proprioception, median age of 25 years (range, 19-33 years), completed the assessment (10 men, 10 women). Interventions: Not applicable. Main Outcome Measures: Precision (consistency in targeting) and accuracy (distance between the intended target and participant result) in UE targeting task using EPP; test-retest repeatability between sessions. Results: Both precision and accuracy were significantly decreased in the eyes-closed condition compared with the eyes-open condition regardless of targeting with dominant or nondominant hand (all P<.001). In the eyes-open condition, there was a dominance effect relating to the accuracy; however, in the eyes-closed condition, accuracy between dominant and nondominant hands was statistically equivalent. Based on minimum detectable change with 95% confidence, there was no change in either metric between the first and second sessions. Conclusions: The results of this study support the feasibility of using this assessment to measure EPP-based on the definition of EPP as a learned skill that indicates control over an external, simple tool-because they demonstrate reliance on proprioception in the eyes-closed condition, symmetry in proprioceptive accuracy between hands for within-participant control, and test-retest reliability for longitudinal measurements. The results also establish normative values for this assessment in young, healthy adults. Further research is required in a clinical population to evaluate the UE proprioceptive targeting task assessment further and collect objective data on EPP.

2.
Med Eng Phys ; 93: 1-7, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34154769

RESUMO

Percutaneous osseointegrated (OI) devices have an endoprosthesis attached to the residual bone of an amputated limb, then pass permanently through the skin to be connected to the distal prosthetic componentry outside of the body. Whether the bone-anchoring region of current OI endoprostheses are cylindrical, and/or conical, they require intimate bone-endoprosthesis contact to promote stabilizing bone attachment. However, removing too much cortical bone to achieve more contact leads to thinner and, subsequently, weaker cortical walls. Endoprostheses need to be designed to balance these factors, namely maximizing the contact, while minimizing the volume of bone removed. In this study, 27 human tibias were used to develop and validate a virtual implantation method. Then, 40 additional tibias were virtually implanted with mock cylindrical and conical bone-anchoring regions at seven residual limb lengths to measure resultant bone-endoprosthesis contact and bone removal. The ratio of bone-endoprosthesis contact to bone volume removed showed the conical geometry had more contact area per volume bone removed for all amputation levels (p ≤ 0.001). In both mock devices, cortical penetration of the endoprosthesis at 20% residual length occurred in 74% of cases evaluated, indicating that alternative endoprosthesis geometries may be needed for clinical success in that region of bone.


Assuntos
Amputados , Tíbia , Amputação Cirúrgica , Osso Cortical , Humanos , Osseointegração , Próteses e Implantes , Desenho de Prótese , Implantação de Prótese , Tíbia/cirurgia
3.
Front Rehabil Sci ; 22021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-35178528

RESUMO

Cadaveric mechanical testing of a percutaneous osseointegration docking system (PODS) for osseointegration (OI) prosthetic limb attachment revealed that translation of the exact system from the humerus to the tibia may not be suitable. The PODS, designed specifically for the humerus achieved 1.4-4.8 times greater mechanical stability in the humerus than in the tibia despite morphology that indicated translational feasibility. To better understand this discrepancy, finite element analyses (FEAs) modeled the implantation of the PODS into the bones. Models from cadaveric humeri (n = 3) and tibia (n = 3) were constructed from CT scans, and virtual implantation preparation of an array of endoprosthesis sizes that made contact with the endosteal surface but did not penetrate the outer cortex was performed. Final impaction of the endoprosthesis was simulated using a displacement ramp function to press the endoprosthesis model into the bone. Impaction force and maximum first principal (circumferential) stress were recorded to estimate stability and assess fracture risk of the system. We hypothesized that the humerus and tibia would have different optimal PODS sizing criteria that maximized impaction force and minimized first principal stress. The optimal sizing for the humerus corresponded to implantation instructions, whereas for the tibia optimal sizing was three times larger than the guidelines indicated. This FEA examination of impaction force and stress distribution lead us to believe that the same endoprosthesis strategy for the humerus is not suitable for the tibia because of thin medial and lateral cortices that compromise implantation.

4.
Anat Rec (Hoboken) ; 304(3): 507-517, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32585072

RESUMO

Bone resorption caused by stress shielding and insufficient bone-implant contact continues to be problematic for orthopedic endoprostheses that utilize osseointegration (OI) for skeletal fixation. Morphologic analyses have helped combat this issue by defining anatomic parameters to optimize endoprosthesis loading by maximizing bone-implant contact. These studies have not typically included diaphyseal medullary morphology, as this region is not pertinent to total joint replacement. To the contrary, percutaneous OI endoprostheses for prosthetic limb attachment are placed in the diaphysis of the long bone. This study examined the cortical and medullary morphology of 116 fresh-frozen human cadaveric tibia using computed tomography. Anatomic landmarks were selected and custom MATLAB scripts were used to analyze the cross-sectional cortical and medullary morphology normalized to biomechanical length (BML). BML measured the distance between the tibial plateau and the tibial plafond. Properties such as cortical thickness, medullary diameter, and circularity of the medullary canal were quantified. We tested the influence of sex and laterality on morphology, and examined variations along the length of the bone. Results showed that while both sex and laterality impacted the location of anatomic landmarks, only sex influenced cross-sectional morphology. Overall, morphology significantly affected shape along the length of the bone for all examined properties except medullary circularity. This analysis found that distal to 35% BML, the canal is conducive to a circular implant, with medullary diameter ranging from 13 to 32 mm between 20 and 80% BML. A large size range is necessary for sufficient implant contact in order to accommodate residual limb length after amputation.


Assuntos
Osso Cortical/anatomia & histologia , Tíbia/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Osso Cortical/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
PLoS One ; 15(8): e0237179, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32760149

RESUMO

Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13-33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12-15%, and axial pullout forces were 30-40% of the intact case (p≤0.001). The myoelectric hook and hand bending moments were 60-99%, torsional moments were 44-97%, and axial pullout forces were 62-101% of the intact case. The advanced prosthesis bending moments were 177-201%, torsional moments were 164-326%, and axial pullout forces were 133-185% of the intact case (p≤0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient's desired terminal device when planning post-operative percutaneous OI rehabilitation and training.


Assuntos
Membros Artificiais/normas , Osseointegração , Torção Mecânica , Suporte de Carga , Membros Artificiais/efeitos adversos , Membros Artificiais/classificação , Fenômenos Biomecânicos , Interface Osso-Implante/fisiologia , Interface Osso-Implante/fisiopatologia , Humanos , Úmero/fisiologia , Úmero/fisiopatologia
6.
Gait Posture ; 80: 49-55, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32485424

RESUMO

BACKGROUND: Percutaneous osseointegrated (OI) docking of prosthetic limbs returns loading directly to the residual bone of individuals with amputations. Lower limb diaphyseal biomechanics have not been studied during the wide range of daily activities performed by individuals with lower extremity amputations; therefore, little is known about the loads experienced at the bone-endoprosthetic interface of a percutaneous OI device. RESEARCH QUESTION: Does residual limb length and/or gender influence loading magnitudes in the diaphysis of the femur or tibia during daily activities? METHODS: This observational study used motion capture data from 40 non-amputee volunteers performing nine activities ranging from low to high demand, to virtually simulate residual limbs of amputees. To simulate diaphyseal bone loading in individuals with lower limb amputations, virtual joints were defined during post-processing at 25, 50, and 75 % of residual limb length of both the femur and the tibia, representing six clinically relevant residual limb lengths for OI device placement. Peak axial distractive and compressive forces, torsional moments, and bending moments were calculated for each activity. Comparisons were made between genders and between different levels of the simulated residual limb. RESULTS: For simulated above and below knee amputations, short residual limbs showed the highest average bending, torsion, and axial distractive loads, while axial compressive loads were highest for long residual limbs. Absolute maxima for all subjects showed this same trend, except in below knee torsion, where 75 % residual tibia length showed the maximum. The highest demand activities yielding peaks in all directions were cutting with right leg planted, jump, run, and fall. SIGNIFICANCE: Overall, individuals with shorter residual limbs experienced higher diaphyseal forces. This should be taken into consideration during surgical implantation of percutaneous OI devices where residual limb length can potentially be shortened, and during rehabilitation of percutaneous OI patients.


Assuntos
Membros Artificiais , Extremidade Inferior/anatomia & histologia , Osseointegração , Suporte de Carga , Adulto , Idoso , Amputados/reabilitação , Fenômenos Biomecânicos , Feminino , Fêmur/anatomia & histologia , Humanos , Joelho , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Tíbia/anatomia & histologia , Tíbia/cirurgia , Adulto Jovem
7.
Clin Biomech (Bristol, Avon) ; 72: 108-114, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31862604

RESUMO

BACKGROUND: Percutaneous osseointegrated devices for skeletal fixation of prosthetic limbs have the potential to improve clinical outcomes in the transhumeral amputee population. Initial endoprosthesis stability is paramount for long-term osseointegration and safe clinical introduction of this technology. We evaluated an endoprosthetic design featuring a distally porous coated titanium stem with proximal slots for placement of bicortical interlocking screws. METHODS: Yield load, ultimate failure load, and construct stiffness were measured in 18 pairs of fresh-frozen and thawed cadaver humeri, at distal and proximal amputation levels, without and with screws, under axial pull-out, torsion, and bending loads. Paired statistical comparisons were performed without screws at the two resection levels, and at distal and proximal levels with and without screws. FINDINGS: Without screws, the location of the amputation influenced the stability only in torsional yield (p = 0.032) and torsional ultimate failure (p = 0.033). Proximally, the torsional yield and the torsional ultimate failure were 44% and 47% of that distally. Screws improved stability. In axial pull-out, screws increased the distal ultimate failure 3.2 times (p = 0.003). In torsion, screws increased the yield at the proximal level 1.9 times (p = 0.035), distal ultimate failure load 3.3 times (p = 0.016) and proximal ultimate failure 6.4 times (p = 0.013). In bending, screws increased ultimate failure at the proximal level 1.6 times (p = 0.026). INTERPRETATION: Proximal slots and bicortical interlocking screws may find application in percutaneous osseointegrated devices for patients with amputations, especially in the less stable proximal bone of a short residual limb.


Assuntos
Amputados , Parafusos Ósseos , Úmero/cirurgia , Fenômenos Mecânicos , Osseointegração , Fenômenos Biomecânicos , Placas Ósseas , Feminino , Humanos , Masculino
8.
Clin Orthop Relat Res ; 478(4): 871-883, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31725479

RESUMO

BACKGROUND: Muscle volume is important in shoulder function. It can be used to estimate shoulder muscle balance in health, pathology, and repair and is indicative of strength based on muscle size. Although prior studies have shown that muscle area on two-dimensional (2-D) images correlates with three-dimensional (3-D) muscle volume, they have not provided equations to predict muscle volume from imaging nor validation of the measurements. QUESTIONS/PURPOSES: We wished to create an algorithm that quickly, accurately, and reliably estimates the volume of the shoulder muscles using cross-sectional area on MR images with low error. Specifically, we wished to (1) determine which MR imaging planes provide the highest correlation between shoulder muscle cross-sectional area and volume; (2) derive equations to predict muscle volume from cross-sectional area and validate their predictive capability; and (3) quantify the reliability of muscle cross-sectional area measurement. METHODS: Three-dimensional MRI was performed on 10 cadaver shoulders, with sample size chosen for comparison to prior studies of shoulder muscle volume and in consideration of the cost of comprehensive analysis, followed by dissection for muscle volume measurement via water displacement. From each MR series, 3-D models of the rotator cuff and deltoid muscles were generated, and 2-D slices of these muscle models were selected at defined anatomic landmarks. Linear regression equations were generated to predict muscle volume at the plane(s) with the highest correlation between volume and area and for planes identified in prior studies of muscle volume and area. Volume predictions from MR scans of six different cadaver shoulders were also made, after which they were dissected to quantify muscle volume. This validation population allowed the calculation of the predictive error compared with actual muscle volume. Finally, reliability of measuring muscle areas on MR images was calculated using intraclass correlation coefficients for inter-rater reliability, as measured between two observers at a single time point. RESULTS: The rotator cuff planes with the highest correlation between volume and area were the sum of the glenoid face and the midpoint of the scapula, and for the deltoid, it was the transverse plane at the top of the greater tuberosity. Water and digital muscle volumes were highly correlated (r ≥ 0.993, error < 4%), and muscle areas correlated highly with volumes (r ≥ 0.992, error < 2%). All correlations had p < 0.001. Muscle volume was predicted with low mean error (< 10%). All intraclass correlation coefficients were > 0.925, suggesting high inter-rater reliability in determining muscle areas from MR images. CONCLUSION: Deltoid and rotator cuff muscle cross-sectional areas can be reliably measured on MRI and predict muscle volumes with low error. CLINICAL RELEVANCE: Using simple linear equations, 2-D muscle area measurements from common clinical image analysis software can be used to estimate 3-D muscle volumes from MR image data. Future studies should determine if these muscle volume estimations can be used in the evaluation of patient function, changes in shoulder health, and in populations with muscle atrophy. Additionally, these muscle volume estimation techniques can be used as inputs to musculoskeletal models examining kinetics and kinematics of humans that rely on subject-specific muscle architecture.


Assuntos
Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/diagnóstico por imagem , Ombro/anatomia & histologia , Ombro/diagnóstico por imagem , Idoso , Algoritmos , Pontos de Referência Anatômicos , Cadáver , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
9.
Neurology ; 89(19): 2010-2016, 2017 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-29030450

RESUMO

OBJECTIVE: To examine whether blast exposure alone and blast-associated concussion result in similar neurologic and mental health symptoms. METHODS: A 14-item questionnaire was administered to male US Marines on their return from deployment in Iraq and/or Afghanistan. RESULTS: A total of 2,612 Marines (median age 22 years) completed the survey. Of those, 2,320 (88.9%) reported exposure to ≥1 blast during their current and/or prior deployments. In addition, 1,022 (39.1%) reported ≥1 concussion during the current deployment, and 731 (28.0%) had experienced at least 1 prior lifetime concussion. Marines were more likely to have sustained a concussion during the current deployment if they had a history of 1 (odds ratio [OR] 1.5, 95% confidence interval [CI] 1.2-2.0) or ≥1 (OR 2.3, 95% CI 1.7-3.0) prior concussion. The most common symptoms were trouble sleeping (38.4%), irritability (37.9%), tinnitus (33.8%), and headaches (33.3%). Compared to those experiencing blast exposure without injury, Marines either experiencing a concussion during the current deployment or being moved or injured by a blast had an increased risk of postinjury symptoms. CONCLUSIONS: There appears to be a continuum of increasing total symptoms from no exposure to blast exposure plus both current deployment concussion and past concussion. Concussion had a greater influence than blast exposure alone on the presence of postdeployment symptoms. A high blast injury score can be used to triage those exposed to explosive blasts for evaluation.


Assuntos
Traumatismos por Explosões/complicações , Concussão Encefálica/etiologia , Síndrome Pós-Concussão/etiologia , Adulto , Campanha Afegã de 2001- , Concussão Encefálica/diagnóstico , Cefaleia/etiologia , Humanos , Guerra do Iraque 2003-2011 , Humor Irritável/fisiologia , Masculino , Militares/estatística & dados numéricos , Síndrome Pós-Concussão/diagnóstico , Distúrbios do Início e da Manutenção do Sono/etiologia , Zumbido/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...